LT-10830-C
Page 1 of 4
General Information
Specifications
FT520-84 Regeneration
Control Instructions
Power 115 VAC (220 VAC optional)
50/60 Hz; 12-24 VDC
Temperature 32° - 130° F (0° - 55° C)
Enclosure Precision cast aluminum,
NEMA 4X
Initiation Outputs Two Form C SPDT relay,
115 VAC 5A max
Max Pulse Output 100 mA at 60 VDC
Memory Type Non-volatile EEPROM
auto-backup
Sensor Power 12 VDC, 10 mA
Totalizer 8 digit
Rate Display 5 digit
Volume Units Gallons, cubic feet, cubic
meters, liters, million gallons
Output Time 1-999 Seconds
Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC,
opto-isolated
Sensor Input Open collector current sink,
ESD protected
Max Input Frequency 1,000 Hz
Shipping Weight 7 lbs
Features
Easy-read
backlit display
Remote control terminals
(inside housing)
Rugged cast aluminum
housing
(wall or panel mount)
Chemical pump
pulse LED
Regeneration
initiation
Regeneration volume
counts down
The FT520-84 is a version of the SeaMetrics flow
processor specially designed for regeneration control.
On the input side, it can be used with SeaMetrics flow
sensors and meters, as well as with water meters from
other manufacturers. The output can be used to initiate
regeneration in a variety of one-tank and two-tank water
treatment systems. In addition to the regeneration
functions, this unit features displays of flow rate and
accumulated flow, as well as programmable pulse output
and a 4-20 mA analog output, for use with remote
recorders.
There are two regeneration relays, which can be used
for alternating regeneration of two tanks. The outputs
remain on for a duration programmed by the user,
depending on the requirements of the regeneration valve
being used.
A programmable pulse output can be used as needed to
control a chemical metering pump, for controlled chem-
ical addition to the water stream.
SET REGEN. VOL.
1000.00 GAL
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Control Instructions

LT-10830-CPage 1 of 4General InformationSpecificationsFT520-84 RegenerationControl InstructionsPower 115 VAC (220 VAC optional) 50/60 Hz; 12-24 VDCTem

Page 2 - Settings

InstallationWall Mounting. Using the four screws provided, attachthe two foot brackets to the sides of the enclosure. Thenattach the unit to any sec

Page 3 - Customer Supplies

3 of 4ConnectionsSeaMetrics flow meters and flow sensor fittings. Onadjustable flow sensors, the K-factor must be taken fromthe chart in the flow sens

Page 4 - 6.03"

19026 72nd Ave South., Kent, WA 98032 USAPhone: 253-872-0284 Fax: 253-872-0285www.seametrics.com 1-800-975-8153Connection for Alternating TanksPane